JCM
Part
No
.
960
-
000053R
_
Rev
.
6
©
2007,
JCM
-
American
Corporation
6
-
7
Programming
and
Testing
AD
-
02
Retrievable
Bill
Validator
Section
6
Table
6
-
2
lists
the
functions
for
the
Drive
Motor
Operation
Test
Numbers
shown
in
Figure
6
-
21
.
6
.
Press
Status
Switch
SW1
to
advance
to
the
next
test
.
Test
#4
Solenoid
Operational
Test
To
initiate
a
Solenoid
Operational
Test
proceed
as
follows:
1
.
Press
Status
Switch
SW1
to
advance
to
Test
#4,
the
Solenoid
Test
(
See
Figure
6
-
22
a)
.
2
.
Press
Status
Switch
SW3
to
select
the
solenoid
being
tested
(See
Figure
6
-
22
b)
.
3
.
Press
Status
Switch
SW2
to
begin
the
selected
solenoid
test
(
See
Figure
6
-
22
c)
.
4
.
Press
Status
Switch
SW2
to
end
the
solenoid
test
(
See
Figure
6
-
22
d)
.
Table
6
-
3
lists
the
functions
for
the
Solenoid
Operation
Test
Numbers
shown
in
Figure
6
-
22
.
5
.
Either
test
another
solenoid
or
end
the
Solenoid
Test
by
pressing
Status
Switch
SW1
again
.
Test
#5
Motor
Functional
Test
The
Motor
Functional
Test
provides
a
detachment
operation,
bill
-
pressing
operation,
and
dispense/
reject
operational
test
.
To
initiate
a
Motor
Functional
Test
proceed
as
follows:
1
.
Press
Status
Switch
SW1
to
advance
to
Test
#5,
the
Motor
Functional
Test
(
See
Figure
6
-
23
a)
.
2
.
Press
Status
Switch
SW3
to
select
the
motor
operation
being
tested
(
See
Figure
6
-
23
b)
.
3
.
Press
Status
Switch
SW2
to
begin
the
selected
test
(
See
Figure
6
-
23
c)
.
4
.
At
this
point
either
test
another
motor
func
-
tion
using
Status
Switches
SW3
and
SW2
Table
6
-
2
Motor
Test
Functions
Motor
Test
No
.
Test
Function
1
Validator
Drive
Motor,
Forward
Rotation
(insert
direction)
2
Validator
Drive
Motor,
Reverse
Rotation
(dispense
direction)
3
Bin
1
Dispense
Motor,
Forward
Rotation
(dispense
direction)
4
Bin
1
Dispense
Motor,
Reverse
Rotation
(insert
direction)
5
Bin
2
Dispense
Motor,
Forward
Rotation
(dispense
direction)
6
Bin
2
Dispense
Motor,
Reverse
Rotation
(insert
direction)
7
Bin
3
Dispense
Motor,
Forward
Rotation
(dispense
direction)
8
Bin
3
Dispense
Motor,
Reverse
Rotation
(insert
direction)
9
Bin
4
Dispense
Motor,
Forward
Rotation
(dispense
direction)
10
Bin
4
Dispense
Motor,
Reverse
Rotation
(insert
direction)
11
Transport
Motor,
Forward
Rotation
(insert
direction)
12
Transport
Motor,
Reverse
Rotation
(dispense
direction)
13
Dispense/Reject
Motor,
Forward
Rotation
(dispense
direction)
14
Dispense/Reject
Motor,
Reverse
Rotation
(insert
direction)
15
Lifter
Motor,
Regular
Rotation
16
Bulk
Loader
Drive
Motor,
Forward
Rotation
(insert
direction)
17
Bulk
Loader
Drive
Motor,
Reverse
Rotation
(dispense
direction)
18
Pusher
Drive
Motor,
Regular
Rotation
Table
6
-
3
Solenoid
Test
Functions
Solenoid
Test
No
.
Solenoid
Function
1
Switch
Solenoid
1
2
Switch
Solenoid
2
3
Switch
Solenoid
3
4
Dispense
Shutter
Solenoid
5
Dispense/Deposit
Divert
Solenoid
Figure
6
-
22
Solenoid
Operational
Test
Press
SW1
to
Locate
Test
Press
SW3
to
Select
Test
b
Press
SW2
c
d
to
Test
Solenoid
Solenoid
a
o
n
o
ff
Press
SW2
again
to
End
Test
NOTE:
If
Test
Operation
01
does
not
begin
when
SW2
is
pressed,
go
to
Operation
02
.
After
performing
that
test,
cycle
SW3
back
to
Test
1
and
re
-
press
SW2
again
.
Then
proceed
to
Test
03
by
pressing
SW3
again
.