JCM Part No . 960 - 000053R _ Rev . 6 © 2007, JCM - American Corporation 6 - 7 Programming and Testing AD - 02™ Retrievable Bill Validator Section 6 Table 6 - 2 lists the functions for the Drive Motor Operation Test Numbers shown in Figure 6 - 21 . 6 . Press Status Switch SW1 to advance to the next test . Test #4 Solenoid Operational Test To initiate a Solenoid Operational Test proceed as follows: 1 . Press Status Switch SW1 to advance to Test #4, the Solenoid Test ( See Figure 6 - 22 a) . 2 . Press Status Switch SW3 to select the solenoid being tested (See Figure 6 - 22 b) . 3 . Press Status Switch SW2 to begin the selected solenoid test ( See Figure 6 - 22 c) . 4 . Press Status Switch SW2 to end the solenoid test ( See Figure 6 - 22 d) . Table 6 - 3 lists the functions for the Solenoid Operation Test Numbers shown in Figure 6 - 22 . 5 . Either test another solenoid or end the Solenoid Test by pressing Status Switch SW1 again . Test #5 Motor Functional Test The Motor Functional Test provides a detachment operation, bill - pressing operation, and dispense/ reject operational test . To initiate a Motor Functional Test proceed as follows: 1 . Press Status Switch SW1 to advance to Test #5, the Motor Functional Test ( See Figure 6 - 23 a) . 2 . Press Status Switch SW3 to select the motor operation being tested ( See Figure 6 - 23 b) . 3 . Press Status Switch SW2 to begin the selected test ( See Figure 6 - 23 c) . 4 . At this point either test another motor func - tion using Status Switches SW3 and SW2 Table 6 - 2 Motor Test Functions Motor Test No . Test Function 1 Validator Drive Motor, Forward Rotation (insert direction) 2 Validator Drive Motor, Reverse Rotation (dispense direction) 3 Bin 1 Dispense Motor, Forward Rotation (dispense direction) 4 Bin 1 Dispense Motor, Reverse Rotation (insert direction) 5 Bin 2 Dispense Motor, Forward Rotation (dispense direction) 6 Bin 2 Dispense Motor, Reverse Rotation (insert direction) 7 Bin 3 Dispense Motor, Forward Rotation (dispense direction) 8 Bin 3 Dispense Motor, Reverse Rotation (insert direction) 9 Bin 4 Dispense Motor, Forward Rotation (dispense direction) 10 Bin 4 Dispense Motor, Reverse Rotation (insert direction) 11 Transport Motor, Forward Rotation (insert direction) 12 Transport Motor, Reverse Rotation (dispense direction) 13 Dispense/Reject Motor, Forward Rotation (dispense direction) 14 Dispense/Reject Motor, Reverse Rotation (insert direction) 15 Lifter Motor, Regular Rotation 16 Bulk Loader Drive Motor, Forward Rotation (insert direction) 17 Bulk Loader Drive Motor, Reverse Rotation (dispense direction) 18 Pusher Drive Motor, Regular Rotation Table 6 - 3 Solenoid Test Functions Solenoid Test No . Solenoid Function 1 Switch Solenoid 1 2 Switch Solenoid 2 3 Switch Solenoid 3 4 Dispense Shutter Solenoid 5 Dispense/Deposit Divert Solenoid Figure 6 - 22 Solenoid Operational Test Press SW1 to Locate Test Press SW3 to Select Test b Press SW2 c d to Test Solenoid Solenoid a o       n o       ff Press SW2 again to End Test NOTE: If Test Operation 01 does not begin when SW2 is pressed, go to Operation 02 . After performing that test, cycle SW3 back to Test 1 and re - press SW2 again . Then proceed to Test 03 by pressing SW3 again .