JCM Part No . 960 - 000053R _ Rev . 6 © 2007, JCM - American Corporation 6 - 8 Section 6 AD - 02™ Retrievable Bill Validator Programming and Testing respectively, or press Status Switch SW1 to end Motor Functional Test ( See Figure 6 - 23 d) . Table 6 - 4 lists the operations for the Motor Functional Test Numbers shown in Figure 6 - 23 . 5 . Press Status Switch SW1 to advance to the next test . Test #6 Unit Operational Test To initiate a Unit Operational Test proceed as follows: 1 . Press Status Switch SW1 to advance to Test #6, the Unit Operational Test ( See Figure 6 - 24 a) . 2 . Press Status Switch SW3 and select Test M1 (Normal Mode), or Test M2 (Automatic Mode), and press Status Switch SW1 after selecting the desired mode . In Normal mode, the machine dispenses the number of bills requested . Pressing Status Switch SW3 will dispense another group of the same number of bills unless the number of bills requested is changed by pressing Status Switch SW1 or SW2 . In automatic mode, the machine dispenses the number of bills requested . When those bills are removed from the dispenser slot, the machine automatically dispenses the same number of bills again . It will keep repeating this process until the bin is empty . If the last bills dispensed are less than the total amount requested, the bills will go into the holding tray instead . The only way to change the mode selection is to turn the DC Power OFF, turn it back ON and cycle Status Switch SW1 to Test #6 . 3 . Press Status Switch SW3 to dispense the selected amount bills . If there are insufficient bills in the selected bin, all of the bills in that bin will be placed in the holding tray . Test #7 Error Log Indicator Test To initiate an Error Log Indicator Test proceed as follows: 1 . Press Status Switch SW1 to advance to Test #7, the Error Log Indicator Test ( See Figure 6 - 25 a through e) . 2 . While proceeding through the Figure 6 - 25 procedure, refer to the following two tables ( Table 6 - 5 & Table 6 - 6) when performing Tests ‘d5’ and ‘d6’ respectively . Table 6 - 4 Motor Functional Test Operations Motor Test No . Functional Operation 1 Upper Lifter Operation (Up) 2 Upper Lifter Operation (Down) 3 Lower Lifter Operation (Up & Down) 4 Dispensing Pusher Operation 5 Dispensing Pusher Operation (Up) 6 Dispensing Pusher Operation (Down) 7 Dispenser Belt Homing Operation (Dispense Direction) 8 Dispenser Belt Homing Operation (Reject Direction) Figure 6 - 23 Motor Functional Test Press SW1 to Locate Test Press SW3 to Select Test b Press SW2 c d to Test Motor Motor a o          n o          ff Press SW1 to End Test NOTE: Use Status Switches SW1 and SW2 to respectively increase or decrease the number of bills dispensed from the bin selected by setting DIP Switches 1 throug h 4 . A maximum of 20 bills can be dispensed at one time . Figure 6 - 24 Unit Operational Test a b Press SW1 to Locate Test Press SW3 to Select Test M1 or M2 Press SW2 to Set Amount of Bills to be Dispensed Indicates that 18 Bills will be Dispensed from the Bin Turn Power OFF to End this Test . m       1 m       2 c NOTE: In this case, if there are not 18 bills in the selected bin, all of the bills in that bin were placed in the holding tray . m         1 18 Bills d e