JCM
Part
No
.
960
-
000053R
_
Rev
.
6
©
2007,
JCM
-
American
Corporation
6
-
8
Section
6
AD
-
02
Retrievable
Bill
Validator
Programming
and
Testing
respectively,
or
press
Status
Switch
SW1
to
end
Motor
Functional
Test
(
See
Figure
6
-
23
d)
.
Table
6
-
4
lists
the
operations
for
the
Motor
Functional
Test
Numbers
shown
in
Figure
6
-
23
.
5
.
Press
Status
Switch
SW1 to
advance
to
the
next
test
.
Test
#6
Unit
Operational
Test
To
initiate
a
Unit
Operational
Test
proceed
as
follows:
1
.
Press
Status
Switch
SW1
to
advance
to
Test
#6,
the
Unit
Operational
Test
(
See
Figure
6
-
24
a)
.
2
.
Press
Status
Switch
SW3
and
select
Test
M1
(Normal
Mode),
or
Test
M2
(Automatic
Mode),
and
press
Status
Switch
SW1
after
selecting
the
desired
mode
.
In
Normal
mode,
the
machine
dispenses
the
number
of
bills
requested
.
Pressing
Status
Switch
SW3
will
dispense
another
group
of
the
same
number
of
bills
unless
the
number
of
bills
requested
is
changed
by
pressing
Status
Switch
SW1
or
SW2
.
In
automatic
mode,
the
machine
dispenses
the
number
of
bills
requested
.
When
those
bills
are
removed
from
the
dispenser
slot,
the
machine
automatically
dispenses
the
same
number
of
bills
again
.
It
will
keep
repeating
this
process
until
the
bin
is
empty
.
If
the
last
bills
dispensed
are
less
than
the
total
amount
requested,
the
bills
will
go
into
the
holding
tray
instead
.
The
only
way
to
change
the
mode
selection
is
to
turn
the
DC
Power
OFF,
turn
it
back
ON
and
cycle
Status
Switch
SW1
to
Test
#6
.
3
.
Press
Status
Switch
SW3
to
dispense
the
selected
amount
bills
.
If
there
are
insufficient
bills
in
the
selected
bin,
all
of
the
bills
in
that
bin
will
be
placed
in
the
holding
tray
.
Test
#7
Error
Log
Indicator
Test
To
initiate
an
Error
Log
Indicator
Test
proceed
as
follows:
1
.
Press
Status
Switch
SW1
to
advance
to
Test
#7,
the
Error
Log
Indicator
Test
(
See
Figure
6
-
25
a
through
e)
.
2
.
While
proceeding
through
the
Figure
6
-
25
procedure,
refer
to
the
following
two
tables
(
Table
6
-
5
&
Table
6
-
6)
when
performing
Tests
d5
and
d6
respectively
.
Table
6
-
4
Motor
Functional
Test
Operations
Motor
Test
No
.
Functional
Operation
1
Upper
Lifter
Operation
(Up)
2
Upper
Lifter
Operation
(Down)
3
Lower
Lifter
Operation
(Up
&
Down)
4
Dispensing
Pusher
Operation
5
Dispensing
Pusher
Operation
(Up)
6
Dispensing
Pusher
Operation
(Down)
7
Dispenser
Belt
Homing
Operation
(Dispense
Direction)
8
Dispenser
Belt
Homing
Operation
(Reject
Direction)
Figure
6
-
23
Motor
Functional
Test
Press
SW1
to
Locate
Test
Press
SW3
to
Select
Test
b
Press
SW2
c
d
to
Test
Motor
Motor
a
o
n
o
ff
Press
SW1
to
End
Test
NOTE:
Use
Status
Switches
SW1
and
SW2
to
respectively
increase
or
decrease
the
number
of
bills
dispensed
from
the
bin
selected
by
setting
DIP
Switches
1
throug
h
4
.
A
maximum
of
20
bills
can
be
dispensed
at
one
time
.
Figure
6
-
24
Unit
Operational
Test
a
b
Press
SW1
to
Locate
Test
Press
SW3
to
Select
Test
M1
or
M2
Press
SW2
to
Set
Amount
of
Bills
to
be
Dispensed
Indicates
that
18
Bills
will
be
Dispensed
from
the
Bin
Turn
Power
OFF
to
End
this
Test
.
m
1
m
2
c
NOTE:
In
this
case,
if
there
are
not
18
bills
in
the
selected
bin,
all
of
the
bills
in
that
bin
were
placed
in
the
holding
tray
.
m
1
18
Bills
d
e