JCM Part No . 960 - 000053R _ Rev . 6 © 2007, JCM - American Corporation 6 - 11 Programming and Testing AD - 02™ Retrievable Bill Validator Section 6 12 . . Go to the upper menu bar, click on the “Transfer” drop down menu, select “Capture Text” and the Figure 6 - 29 Screen will appear . 13 . Enter a File name in the area provided and click on the Start Screen Button . 14 . On the AD - 02™ Control Panel, press SW1 until Test T7 is displayed ( See Figure 6 - 30 a & b) . 15 . Press SW3 until a d7 is displayed (See Figure 6 - 30 c) . 16 . Press Status Switch SW1 again to start the Error Log transfer sequence . The Figure 6 - 31 Hyper Terminal report example describes how many bills of different denominations have been inserted and distributed, any rejects that occurred and why, and the number of times each error code was displayed . Refer to the Error Codes listed in Table 6 - 6 on page 9 for a detailed description of the specific error detected . C LEARING THE E RROR L OG Perform the following steps to clear an Error Log File: 1 . With the AD - 02™ power turned OFF, set DIP Switches #2 through #8 to ON and turn the AD - 02™ power ON ( See Figure 6 - 32 a) . 2 . When CLr is displayed, press SW2 (See Figure 6 - 32 b) . When End is displayed, the Error Log data has been cleared ( See Figure 6 - 32 c) . Test #8 Counting Sensor Calibration This test adjusts each Counting Sensor and regis - ters the corresponding adjustment data . Figure 6 - 28 COM Properties Screen Figure 6 - 29 Capture Text Screen Figure 6 - 30 AD - 02 Control Panel Test 7 a b c Figure 6 - 31 Typical Hyper Terminal Data Display Figure 6 - 32 AD - 02 Error Log DIP Switch Setting and Display Indication C         L          r a b c E         n          d Press SW2 when CLr is displayed . When End appears, the data log has been cleared . NOTE: During the Counting Sensor Adjustment, do not expose the Sensor to ambient light; and clean any accumulated dust off the Sensor before making any adjustments .