JCM
Part
No
.
960
-
000053R
_
Rev
.
6
©
2007,
JCM
-
American
Corporation
6
-
11
Programming
and
Testing
AD
-
02
Retrievable
Bill
Validator
Section
6
12
.
.
Go
to
the
upper
menu
bar,
click
on
the
Transfer
drop
down
menu,
select
Capture
Text
and
the
Figure
6
-
29
Screen
will
appear
.
13
.
Enter
a
File
name
in
the
area
provided
and
click
on
the
Start
Screen
Button
.
14
.
On
the
AD
-
02
Control
Panel,
press
SW1
until
Test
T7
is
displayed
(
See
Figure
6
-
30
a
&
b)
.
15
.
Press
SW3
until
a
d7
is
displayed
(See
Figure
6
-
30
c)
.
16
.
Press
Status
Switch
SW1
again
to
start
the
Error
Log
transfer
sequence
.
The
Figure
6
-
31
Hyper
Terminal
report
example
describes
how
many
bills
of
different
denominations
have
been
inserted
and
distributed,
any
rejects
that
occurred
and
why,
and
the
number
of
times
each
error
code
was
displayed
.
Refer
to
the
Error
Codes
listed
in
Table
6
-
6
on
page
9
for
a
detailed
description
of
the
specific
error
detected
.
C
LEARING
THE
E
RROR
L
OG
Perform
the
following
steps
to
clear
an
Error
Log
File:
1
.
With
the
AD
-
02
power
turned
OFF,
set
DIP
Switches
#2
through
#8
to
ON
and
turn
the
AD
-
02
power
ON
(
See
Figure
6
-
32
a)
.
2
.
When
CLr
is
displayed,
press
SW2
(See
Figure
6
-
32
b)
.
When
End
is
displayed,
the
Error
Log
data
has
been
cleared
(
See
Figure
6
-
32
c)
.
Test
#8
Counting
Sensor
Calibration
This
test
adjusts
each
Counting
Sensor
and
regis
-
ters
the
corresponding
adjustment
data
.
Figure
6
-
28
COM
Properties
Screen
Figure
6
-
29
Capture
Text
Screen
Figure
6
-
30
AD
-
02
Control
Panel
Test
7
a
b
c
Figure
6
-
31
Typical
Hyper
Terminal
Data
Display
Figure
6
-
32
AD
-
02
Error
Log
DIP
Switch
Setting
and
Display
Indication
C
L
r
a
b
c
E
n
d
Press
SW2
when
CLr
is
displayed
.
When
End
appears,
the
data
log
has
been
cleared
.
NOTE:
During
the
Counting
Sensor
Adjustment,
do
not
expose
the
Sensor
to
ambient
light;
and
clean
any
accumulated
dust
off
the
Sensor
before
making
any
adjustments
.