JCM Part No . 960 - 000053R _ Rev . 6 © 2007, JCM - American Corporation 6 - 1 2 Section 6 AD - 02™ Retrievable Bill Validator Programming and Testing T HROUGH B EAM L EVEL A DJUSTMENT To initiate a Through Beam Level Counting Sensor Calibration Adjustment proceed as follows: 1 . Press Status Switch SW1 to advance to Test #8, the Counting Sensor Calibration Proce - dure (See Figure 6 - 33 a) . 2 . When T8 is displayed, set DIP Switch #1 to ON and press SW3 ( See Figure 6 - 33 b & c) . 3 . When ST is displayed, press SW3 again to obtain byPo ( See Figure 6 - 33 d & e) .    B ASE U NIT C OUNTING S ENSOR ADJUSTMENT To initiate a Base Unit Counting Sensor adjustment proceed as follows: 1 . Insert Yupo #80 Calibration Paper (JCM Part No . 501 - 000172R) between the transmitter and receiver of the Base Unit Counting Sensor (See Figure 6 - 34 “a” for location) . 2 . Press Switch SW2 again to begin the test (Review Figure 6 - 33 d) . The unit will make the necessary adjustment and then displays byPo (Review Figure 6 - 33 e) . U NIT T HREE C OUNTING S ENSOR ADJUSTMENT To initiate a Unit Three Counting Sensor adjust - ment proceed as follows: 1 . Insert Yupo #80 Calibration Paper between the transmitter and receiver of the Unit Three Counting Sensor ( See Figure 6 - 34 “b” for location) . 2 . Press Switch SW2 again to begin the test ( See Figure 6 - 33 f) . The unit will make the necessary adjustment and then displays 3yPo ( See Figure 6 - 33 g) . U NIT T WO C OUNTING S ENSOR ADJUSTMENT To initiate a Unit Two Counting Sensor adjustment proceed as follows: 1 . Insert Yupo #80 Calibration Paper between the transmitter and receiver of the Unit Two Figure 6 - 33 Unit Counting Sensor Calibration Adjustments Press SW1 to Begin Test Set DIP Switch #1 ON Press SW3 to obtain “Start” (ST) . When ST is displayed, press SW3 again to obtain “byPo” . The unit will display byPo when the Through Beam adjustment is complete . When ST is again displayed, Press SW2 to obtain “3yPo” . The unit will display 3bPo when the Unit Three adjustment is complete . When ST is again displayed, Press SW2 to obtain “2yPo” . The unit will display 2bPo when the Unit Two adjustment is complete . When ST is again displayed, Press SW2 to obtain “1yPo” . The unit will display 1bPo when the Unit One adjustment is complete . b c d a S         T b         y          P          o T          8 e 3         y          P          o S         T f S         T 2         y          P          o g h S         T i j 1         y          P          o k Figure 6 - 34 Count Sensor Adjustment Steps a #80 Paper in Base Unit Place YUPO #80 Paper in Unit 3 Count Place YUPO b Sensor @ #11 Count Sensor #80 Paper in Unit 2 Count Place YUPO Sensor @ #10 c #80 Paper in Unit 1 Count Place YUPO Sensor @ #9 d NOTE: Press SW2 following each YUPO Paper replacement! (shown open)