JCM
Part
No
.
960
-
000053R
_
Rev
.
6
©
2007,
JCM
-
American
Corporation
6
-
1
6
Section
6
AD
-
02
Retrievable
Bill
Validator
Programming
and
Testing
Cleaning
Card
Mode
Activation
To
begin
this
portion
of
the
test
proceed
as
follows:
1
.
Record
the
switch
settings
currently
set
on
DIP
Switch
SW1
and
follow
Figure
6
-
43
procedural
Steps
a
to
e
.
2
.
Apply
a
50%
Ethyl
Alcohol
cleaning
solution
to
the
front
and
back
of
a
standard
AD
-
02
cleaning
sheet
inside
the
broken
line
shown
in
Figure
6
-
44
(JCM
Part
No
.
900
-
100843R)
.
3
.
In
a
single
cleaning
sequence,
pass
the
sheet
three
or
four
times
repeatedly
through
the
machine
from
the
Entry
Slot
to
the
Exit
Slot
(
See
Figure
6
-
45)
.
Counting
Sensor
Adjustment
(Part
1)
Prior
to
re
-
adjustment,
dust
off
all
Sensor
surfaces
.
Figure
6
-
46
provides
the
steps
and
display
results
necessary
to
begin
performing
this
test
.
Figure
6
-
42
Cleaning
Mode
Procedure
Press
SW1
to
Locate
Test
.
Press
SW3
to
Begin
the
Cleaning
Process
.
Insert
the
dedicated
cleaning
paper
into
the
Bill
Entry
Slot
.
Once
cleaning
is
complete,
remove
the
cleaning
paper
from
the
Dispensing
Slot
.
Press
SW1
to
End
the
Test
.
a
b
C
L
n
c
d
NOTE:
Make
sure
that
CLN
is
displayed
and
initialization
is
complete
before
proceeding
to
next
step!
e
NOTE:
Insert
only
one
piece
of
cleaning
paper
at
a
time
.
T
1
5
WARNING:
Cleaning
is
required
every
20,000
bill
acceptance/dispense
cycles
or
the
machine
may
stop
functioning
.
The
rollers
and
transfer
belts
can
be
cleaned
more
often
.
NOTE:
This
procedure
is
performed
in
the
Communications
Mode
.
Figure
6
-
43
Cleaning
Mode
Calibration
Procedure
Begin
the
test
by
setting
DIP
Switch
SW1
Switches
1
&
8
to
ON
and
apply
power
to
the
unit
.
Press
SW2
to
Display
T15
Press
SW3
to
Begin
Cleaning
Process
Insert
the
dedicated
cleaning
paper
into
the
Bill
Entry
Slot
.
Once
cleaning
is
complete,
remove
the
paper
from
the
Dispensing
Slot
.
Press
SW1
to
End
the
Test
.
a
b
C
L
N
c
d
T
1
5
NOTE:
Make
sure
that
CLN
is
displayed
and
initialization
is
complete
before
proceeding
to
next
step!
e
NOTE:
Insert
only
one
piece
of
cleaning
paper
at
a
time
.
T
1
5
Figure
6
-
44
Applying
Cleaner
to
Sheet
NOTE:
If
a
JCM
Cleaning
sheet
is
unavailable
when
cleaning
is
necessary,
use
a
flat
piece
of
substitute
paper
having
a
thickness
of
0
.
22mm
(0
.
0086614
inches)
.
WARNING:
Use
of
a
stronger
alcohol
percentage
than
50%
will
damage
the
lenses
and
void
the
warranty
.
Figure
6
-
45
Inserting
Wet
Cleaning
Sheet
Entry
Slot
Exit
Slot
Cleaning
Sheet
NOTE:
When
a
CPU
Circuit
Board
has
been
replaced,
the
Counting
Sensors
must
be
re
-
calibrated
.
Caution:
During
adjustment,
do
not
expose
the
Count
Sensors
to
a
bright
extraneous
light
source!