JCM
Part
No
.
960
-
000053R
_
Rev
.
6
©
2007,
JCM
-
American
Corporation
6
-
1
7
Programming
and
Testing
AD
-
02
Retrievable
Bill
Validator
Section
6
The
second
portion
of
the
Counting
Sensor
re
-
adjustment
procedure
involves
the
use
of
YUPO
#80
Calibration
Paper
again
(JCM
Part
No
.
501
-
000172R)
as
previously
described
in
Test
#8
Counting
Sensor
Calibration
on
page
6
-
11
.
Counting
Sensor
Adjustment
(Part
2)
Through
Beam
Level
Adjustment
To
begin
this
portion
of
the
test,
insert
YUPO
#80
Calibration
Test
Paper
into
the
Unit
at
the
locations
shown
in
Figure
6
-
47
Steps
d
to
a,
while
repeating
the
procedure
outlined
in
Figure
6
-
48
Steps
a
to
f
.
Test
Mode
Program
Version
Confirmation
To
check
the
current
program
version
being
used
for
testing:
1
.
Remove
the
four
(4)
right
side
cover
Phillips
mounting
screws
and
the
right
side
cover
and
2
.
review
Press
SW3
to
display
the
Bin
Sensor
selections
(See
the
Bin
Sensor
Selection
Table
at
Figure
6
-
39
d)
.
on
page
6
-
14
.
3
.
Record
the
current
DIP
Switch
SW1
settings
when
the
version
check
is
complete
.
Manual
Cleaning/Preventive
Maintenance
To
manually
clean
the
lenses,
use
a
lint
-
free
cloth
and
a
mild
non
-
abrasive
detergent
such
as
liquid
dish
soap
mixed
with
water
.
It
is
important
to
keep
the
bill
path,
rollers,
and
belts
clean
.
Use
a
soft
lint
-
free
cloth
or
a
cotton
swab
to
wipe
dirt
and
stains
from
the
surfaces
of
the
magnetic
and
optical
sensors,
rollers
and
belts
.
The
sensor
lenses
are
transparent,
and
made
of
a
polymer
material
.
Handle
them
with
care
.
Figure
6
-
46
YUPO
Paper
Calibration
Procedure
Part
1
Begin
the
test
by
setting
DIP
Switch
SW1
Switches
1
&
8
to
ON
and
apply
power
to
the
unit
.
Press
SW1
to
Display
T8
Press
SW3
to
Select
Model
Press
SW3
to
Select
the
US
Version
(01)
Press
SW3
to
Confirm
Model
=
ST
a
b
w
r
w
r
c
S
T
d
T
8
0
0
0
1
NOTE:
Version
00
=
Model
AD
-
1
-
2
(Japanese
Version),
and
Version
01
=
Model
AD
-
02
-
4
(USA
Version)
.
e
Figure
6
-
47
Count
Sensor
Adjustment
Steps
a
#80
Paper
in
Base
Unit
Place
YUPO
#80
Paper
in
Unit
3
Count
Place
YUPO
b
Sensor
@
#11
Count
Sensor
#80
Paper
in
Unit
2
Count
Place
YUPO
Sensor
@
#10
c
#80
Paper
in
Unit
1
Count
Place
YUPO
Sensor
@
#9
d
NOTE:
Press
SW2
following
each
YUPO
Paper
replacement!
(shown
open)
NOTE:
This
procedure
was
previously
described
in
detail
during
the
Test
#8
Counting
Sensor
Calibration
on
page
6
-
11
.
Figure
6
-
48
Through
&
Direct
Beam
Adjustment
Level
Procedure
Part
2
Press
SW2
to
Display
BYPO
Insert
YUPO
Paper
into
the
Unit
3
Sensor
&
Press
SW2
to
Display
3YPO
Insert
YUPO
Paper
into
the
Unit
2
Sensor
&
Press
SW2
to
Display
2YPO
Insert
YUPO
Paper
into
the
Unit
1
Sensor
&
Press
SW2
to
Display
1YPO
Press
SW2
with
no
Sensor
blockage
.
Press
SW2
to
Save
Settings
in
Memory
.
a
b
c
B
Y
d
NOTE:
Make
sure
that
no
object
blocks
the
Base
Unit,
Unit
1,
Unit
2
or
Unit
3
Count
Sensors
when
performing
the
next
step
.
P
O
3
Y
P
O
2
Y
P
O
1
Y
P
O
C
L
r
E
N
D
e
f