JCM
Part
No
.
960
-
000053R
_
Rev
.
6
©
2007,
JCM
-
American
Corporation
6
-
1
9
Programming
and
Testing
AD
-
02
Retrievable
Bill
Validator
Section
6
located
at
areas
described
for
Sensors
A,
B,
C
and
D
in
Table
6
-
7
.
2
.
Clean
all
rubber
parts
by
wiping
dust
off
using
a
cotton
cloth
soaked
in
the
approved
cleaning
solution
.
In
general,
dust
on
Valida
-
tion
Unit
Sensors
will
cause
an
increased
loading
reject
frequency
(i
.
e
.
,
7
-
Segment
Display
readings
of
V
-
02,
V
-
07
or
V
-
08),
and
dust
on
each
Counting
Sensor
will
cause
a
Unit
level
Error
7
-
Segment
Display
indication
of
E
-
52,
E
-
53,
E
-
54
or
E
-
55
.
Discharge
Unit
Clearance
Adjustment
To
readjust
Discharge
Unit
clearance
tolerances
proceed
as
follows:
1
.
Remove
the
four
(4)
left
side
cover
Phillips
mounting
screws
and
remove
the
left
AD
-
02
side
cover
(
See
Figure
6
-
52)
.
2
.
Slide
the
entire
AD
-
02
Unit
out
to
the
end
of
its
service
slide
.
Use
the
reference
values
listed
in
Table
6
-
8
to
set
the
clearance
adjust
-
ments
located
on
the
Base
Unit
shown
in
Figure
6
-
53
.
Table
6
-
7
Sensor
Test
Descriptions
Sensor
No
.
Sensor
Name
1
Bulk
Note
Feeder
Sensor
(Right)
2
Bulk
Note
Feeder
Sensor
(Left)
3
Pusher
Sensor
(Upper)
4
Pusher
Sensor
(Lower)
5
Passage
Sensor
(Upper)
6
Passage
Sensor
(Lower)
7
Stacking
Sensor
8
Stack
Remaining
Sensor
9
Dispensing
Slot
Sensor
10
Reject
Box
Empty
Sensor
11
Unit
1
Storage
Sensor
12
Unit
2
Storage
Sensor
13
Unit
3
Storage
Sensor
14
Base
Unit
Storage
Sensor
15
Unit
1
Near
-
end
Sensor
16
Unit
2
Near
-
end
Sensor
17
Unit
3
Near
-
end
Sensor
18
Base
Unit
Near
-
end
Sensor
19
Unit
1
Full
Sensor
20
Unit
2
Full
Sensor
21
Unit
3
Full
Sensor
22
Base
Unit
Full
Sensor
23
Transfer
Pulse
Sensor
24
Lifter
Sensor
(Upper)
25
Lifter
Sensor
(Lower)
26
Door
Sensor
27
Unit
Bottom
Micro
-
Switch
28
Bulk
Note
Feeder
Position
Sensor
A
Unit
1
Counting
Sensor
B
Unit
2
Counting
Sensor
C
Unit
3
Counting
Sensor
D
Base
Unit
Counting
Sensor
NOTE:
Table
6
-
7
lists
the
Sensor
ID
Number
descriptions
for
the
numerous
detectors
shown
in
Figure
6
-
51
.
Table
6
-
8
Clearance
Value
Conditions
Condition
Solution
Overlap
Error
(E
-
62)
Narrow
Clearance
Link
Error
(E
-
63)
Narrow
Clearance
Long
Bill
Error
(E
-
60)
Caused
by
the
Link
Narrow
Clearance
Caused
by
Improper
Discharge
Widen
Clearance
NOTE:
This
Base
Unit
clearance
adjustment
should
be
conducted
with
the
unit
drawn
completely
out
on
its
slide
assembly
.
Figure
6
-
52
Removing
AD
-
02
Left
Side
Cover
Remove
4
Mounting
Screws
NOTE:
The
non
-
recycling
Stacker
(that
can
contain
up
to
500
bills)
should
be
set
to
an
extra
large
clearance,
because
it
never
has
to