JCM Part No . 960 - 000053R _ Rev . 6 © 2007, JCM - American Corporation 6 - 2 4 Section 6 AD - 02™ Retrievable Bill Validator Programming and Testing S TATUS 3 (52H) C OMMAND F ORMAT Table 6 - 24 lists the 52 Hex Status Command Format data codes .   Command Text Data: None.   Process Description: Informs on machine status . S TATUS 3 (52H) R ESPONSE F ORMAT Table 6 - 23 lists the 52 Hex Status Response Format data codes .   Response Text Data: 16 Bytes Fixed to 00 (Hex)   Process Description: If Machine Status 1, 2 or 3 changes, this response is sent irrespective of whether a command has been issued or not . Command/Response Sequence and Status Transition Flow Diagrams Figure 6 - 57 and Figure 6 - 58 on pages 6 - 25 and 6 - 26 respectively, diagram the Normal and the Compulsory download conditions present during normal operating conditions . Figure 6 - 59 on page 6 - 27 diagrams an AD - 02™ Status Transition Flowchart Diagram . Table 6 - 24 Status 52 Hex Command Format Bit Command Code 1 Command Code 2 Time Data Year 3 Time Data Month 4 Time Data Day 5 Time Data Hour 6 Time Data Minute Table 6 - 25 Status 52 Hex Response Format Bit Command Code 1 Response Code 2 Response Parameter 3 Machine Status 1 4 Machine Status 2 5 Machine Status 3 6 Bill Storage Condition 1 7 Bill Storage Condition 2 8 Error Code 9 to 24 Response Text Data