JCM Part No . 960 - 000058R _ Rev . 2 © 2008,   JCM - American Corporation 2 4 Section A EBA - 03 Bill Validator If a Bill is not accepted or rejected, refer to the Red and Green LEDs located on the EBA - 03 for the Error Code generated as listed in Table A - 2 and Table A - 3 on this page . If the Acceptor does not accept a bill, count how man y times the Red LED flashes to determine the possible malfunctions requiring correction (See Table A - 2 in Error Codes on this page) . If the Acceptor rejects a bill, count how many times th e Green LED flashes to determine the possible malfunctions requiring correction (See Table A - 3 in Error Codes on this page) . Error Codes If the EBA - 03 does not operate properly during the various tests, the Red and Green LED’s on the CPU board will flash . Count the number of Red flashes and refer to the Error Code listing in Table A - 2 to determine the possible cause of the prob - lem, or count the number of Green flashes and refer to the Rejection Code listing in Table A - 3 to determine the possible cause of the problem .    Table A - 2   Red LED Error Codes No . of Red LED Flashes Error Description 1 Reserved 2 Reserved 3 Reserved 4 A bill has stopped in the bill path 5 Acceptor motor speed error Acceptor Sensor out of adjustment 6 Acceptor motor does not rotate Acceptor Sensor malfunction No signal from the Encoder Sensor 7 Reserved 8 Reserved 9 Reserved 10 Reserved 11 Reserved 12 Timing error (Tampering) Table A - 3   Green LED Rejection Codes No . of Green LED Flashes Error Description 1 Crooked Bill Insertion 2 Reserved 3 Bill Jam 4 Optical sensor error 1(Bill size error) 5 Bill feed error 6 Identification error 1(Near error) 7 Optical sensor error 2 (Pattern error) 8 Optical sensor error 3 (Photo level err or) 9 Unacceptable bill returned (Inhibit error) 10 Reject signal input 11 Reserved 12 Back sensor error 13 Bill length error 14 Optical sensor error 4 (Infrared error) 15 Optical sensor error 5 (Unrecognizable bi ll)