Calibration
and
Testing
World
Bill
Acceptor
(WBA®
-
1x/2x
-
SS
&
SS2)
Section 6
5
.
Close
the
Acceptor
Head
and
make
sure
that
the
tabs
on
both
side
of
the
Acceptor
Head
firmly
Click
lock
in
place
(
See
Figure
6
-
7
b)
.
6
.
Click
on
the
OK
Screen
Button
to
start
the
Adjusting
with
White
Reference
Paper
calibration
procedure
.
When
calibration
begins
the
Figure
6
-
8
Screen
will
appear
.
7
.
When
White
Paper
Calibration
is
complete,
the
Figure
6
-
9
Screen
will
appear;
at
this
point
insert
the
Black
Calibration
Paper
(KS
-
031
for
WBA
-
12/13
or
KS
-
033
for
WBA
-
22/23/24/25)
as
shown
in
Figure
6
-
10
and
illustrated
in
Figure
6
-
11
a
respectively
.
8
.
Close
the
Acceptor
Head
and
make
sure
that
the
tabs
on
both
side
of
the
Acceptor
Head
firmly
lock
in
place
(
See
Figure
6
-
11
b)
.
9
.
Click
on
the
OK
Screen
Button
to
start
the
Black
Reference
Paper
calibration
procedure
.
When
calibration
begins
the
Figure
6
-
12
Screen
will
appear
.
When
the
Black
Reference
Paper
calibration
procedure
is
complete,
the
Figure
6
-
5
Screen
will
re
-
appear
(See
Figure
6
-
13)
.
Figure
6
-
6
White
Calibration
Paper
Types
Figure
6
-
7
Inserting
White
Calibration
Paper
a
b
NOTE:
Do
not
move
the
Acceptor
Head
or
the
calibration
paper
during
the
calibration
procedure
.
Figure
6
-
8
White
Calibration
Occurring
Screen
Figure
6
-
9
Black
Paper
Calibration
Screen
Figure
6
-
10
Black
Calibration
Paper
Types
Figure
6
-
11
Inserting
Black
Calibration
Paper
a
b
NOTE:
Do
not
move
the
Acceptor
Head
or
the
calibration
paper
during
the
calibration
procedure
.
Figure
6
-
12
Black
Calibration
Occurring
Screen