JCM
Part
No
.
960
-
000076R
_
Rev
.
1
©
2007,
JCM
-
American
Corporation
6
-
4
Section
6
World
Bill
Acceptor
(WBA®
-
1x/2x
-
SS
&
SS2)
Calibration
and
Testing
10
.
At
this
point
re
-
insert
the
White
Calibration
Paper
and
click
on
the
OK
Screen
Button
to
re
-
start
the
Adjusting
with
White
Reference
Paper
calibration
procedure
again
.
11
.
Repeat
Steps
5
through
9
three
to
five
times
until
the
Figure
6
-
14
Screen
appears
.
Calibration
with
White
and
Black
Paper
is
now
complete
.
Remove
the
final
calibration
paper
and
close
the
Acceptor
Head
(
See
Figure
6
-
15
a)
.
Make
sure
that
the
tabs
on
both
side
of
the
Acceptor
Head
are
once
again
firmly
locked
in
place
(
See
Figure
6
-
15
b)
.
12
.
Click
on
the
OK
Screen
Button
to
start
the
paperless
calibration
procedure
(i
.
e
.
,
no
calibration
paper
inserted)
.
When
calibration
begins
the
Figure
6
-
16
Screen
will
appear
.
13
.
When
the
paperless
calibration
process
is
complete,
the
Figure
6
-
17
Screen
will
appear
.
14
.
Insert
the
MAG
Head
Test
Board
into
the
Acceptor
and
find
the
location
where
the
second
line
of
MAG
Head
Test
Board
just
aligns
above
the
Acceptor
Head
Roller
located
on
the
lower
tray
(See
Figure
6
-
18)
.
Make
sure
that
the
tabs
on
both
side
of
the
Acceptor
Head
are
once
again
firmly
locked
in
place
.
15
.
Click
on
the
OK
Screen
Button
to
start
the
MAG
Head
Tester
Calibration
procedure
.
The
Figure
6
-
19
Screen
will
appear
showing
the
current
value
(a)
and
the
peak
value
(b)
detected
after
the
MAG
Board
has
been
inserted
.
Figure
6
-
13
White
Re
-
Calibration
Request
Screen
Figure
6
-
14
Remove
Calibration
Paper
Screen
Figure
6
-
15
Removing
Final
Calibration
Paper
a
b
Figure
6
-
16
Paperless
Calibration
Screen
Figure
6
-
17
Magnetic
Test
Calibration
Screen
NOTE:
Closing
the
Acceptor
Head
once
the
calibration
process
starts
will
result
in
an
erroneous
reading!
Figure
6
-
18
Aligning
the
MAG
Head
Calibration
Test
Board