TROUBLESHOOTING
This
section
provides
Troubleshooting
instructions
for
the
World
Bill
Acceptor
Series
(WBA)
.
This
section
contains
the
following
information:
Introduction
Troubleshooting
Overview
Fault
Table
Listings
Performance
Tests
LED
Diagnostic
Codes
Introduction
Most
Bill
Acceptor
failures
are
due
to
minor
causes
.
Before
replacing
any
parts,
make
sure
that
all
assembly
and
circuit
board
connectors
are
prop
-
erly
fitted
and
the
harness
is
properly
connected
.
Faulty
bill
acceptance
by
the
Bill
Acceptor
is
often
caused
when
dust
or
iron
powder
adheres
to
the
identification
sensor,
magnetic
sensor
or
Transport
belt
.
Clean
the
acceptor
section
first,
then
observe
the
operating
state
of
the
Bill
Acceptor
in
detail
when
initializing
power
.
This
observation
is
impor
-
tant
in
locating
any
failure
causes
and
the
possible
fault
point
.
If
the
acceptor
head
has
to
be
repaired
by
disassembling
it,
always
recalibrate
the
sensors
following
a
repair
.
Perform
all
repairs
by
referring
to
the
Calibration
and
Flash
Memory
Software
Downloading
section
in
the
Section
7
Adjustment
and
Performance
Test
Section,
and
in
the
Section
4
Assembly/
Disassembly
Instructions
Section
.
Troubleshooting
Overview
The
WBA
allows
the
operator
to
perform
fault
diagnosis
by
checking
various
fault
table
listings
against
the
symptom
and
survey
the
cause(s)
of
any
failure
occurrences
during
the
process
.
After
determining
the
cause
of
the
failure,
execute
the
Performance
Test,
perform
a
sensor
readjust
-
ment
and
then
repair
the
WBA
Unit
replacing
any
appropriate
parts
deemed
necessary
.
Fault
Table
Listings
Table
A
-
1
through
Table
A
-
3
list
the
various
possible
WBA
fault
conditions
that
can
occur
and
the
necessary
actions
required
to
correct
them
.
Table
A
-
1
General
Fault
Conditions
Symptoms/Error
Messages
Possible
Fault
Causes
Corrective
Action
Required
Bill
Acceptor
is
not
working
(does
not
accept
any
bills)
.
No
external
power
is
applied
to
the
Bill
Acceptor
(+12VDC
&
GND)
Verify
that
the
Power
Supply
+12VDC
and
Ground
cables
are
connected
to
the
appropriate
pins
on
the
main
connector
.
NOTE:
The
small
LED
to
the
right
of
the
DIP
Switches
indicates
power
available
when
lit
.
Wrong
or
inappropriate
connections
Verify
that
all
harness
connectors
are
properly
seated
.
Check
for
any
bent,
missing
or
damaged
pins
in
the
connector
plugs
and
mating
receptacles
.
Corrupted
software
.
Re
-
download
the
correct
software
.
Refer
to
Forced
Download
Mode
on
page
A
-
9
of
this
Section
for
software
downloading
instructions
.
CPU
Board
failure
.
Refer
to
the
Performance
Tests
on
page
A
-
4
of
this
Appendix
and
conduct
an
Initial
Operation
Test
.
If
the
test
result
is
Negative
(NG),
replace
the
CPU
Board
.
(For
WBA
-
11/13
only)
The
EPROM
is
inserted
backwards
.
Remove
the
Acceptor
Unit
from
the
frame
.
Remove
the
EPROM
from
CPU
Board
and
reinsert
it
in
the
correct
direction
.