JCM
Part
No
.
960
-
000076R
_
Rev
.
1
©
2007,
JCM
-
American
Corporation
A
-
4
Appendix
A
World
Bill
Acceptor
(WBA®
-
1x/2x
-
SS
&
SS2)
Troubleshooting
Performance
Tests
The
WBA
is
equipped
with
diagnostic
features
to
aid
in
repair
and
maintenance
.
This
portion
of
Appendix
A
describes
the
test
procedure
for
use
with
each
function
using
DIP
Switch
settings
to
identify
the
cause
of
a
failure
condition
.
In
order
to
identify
a
failure
conditions
cause,
the
WBA
has
to
be
in
the
TEST
mode
.
To
enter
the
TEST
mode
perform
the
following
steps:
1
.
On
the
CPU
Board
set
DS1
DIP
Switches
No
.
1
through
7
to
OFF
and
Switch
No
.
8
to
ON
.
2
.
Supply
the
power
to
the
WBA
.
3
.
Check
that
the
Red
diagnostic
LED
blinks
at
a
steady
rate
.
This
condition
indicates
the
unit
is
now
in
the
TEST
mode
.
4
.
Set
the
DIP
Switches
depending
on
the
test
you
wish
to
execute
according
to
Table
A
-
4
through
Table
A
-
12
.
5
.
Set
DIP
Switch
No
.
8
to
OFF
to
start
a
particular
test
.
When
the
test
begins,
the
Red
diagnostic
LED
will
extinguish
(go
out)
.
After
few
seconds,
the
Red
diagnostic
LED
will
independently
turn
ON
&
OFF
depend
-
ing
on
the
test
being
executed
.
6
.
To
finish
a
test,
set
DIP
Switch
No
.
8
to
ON
again,
and
turn
the
WBA
power
OFF
.
Choosing
and
Selecting
Operational
Tests
Set
the
WBA
into
the
Test
Mode,
and
then
set
the
related
DIP
Switches
to
match
each
operational
test
shown
in
the
following
Test
Tables
.
Set
DIP
Switch
8
to
OFF
initially
to
start
each
test
.
Auto
Calibration
Mode
The
Auto
Calibration
Mode
is
entered
by
turning
DS1
DIP
Switches
5,
6,
7
and
8,
to
the
ON
position
and
powering
up
the
unit:
The
unit
will
cycle
once
and
stop
to
receive
the
White
and
Black
reference
papers
Insert
the
calibration
paper
black
end
first
The
unit
will
sample
the
White
Reference
Paper
then
the
Black
Reference
Paper
It
will
do
this
five
(5)
or
more
times
and
then
return
the
calibration
paper
.
If
calibration
fails,
the
Test
LED/Bezel
Light
will
start
to
blink,
then
pause,
blink,
then
pause,
etc
.
Count
the
number
of
blinks
in
between
pauses,
this
number
is
the
error
code
count
(see
the
Calibration
Error
Indication
Table
below
to
identify
the
error)
.
C
ALIBRATION
E
RROR
T
ABLE
Table
A
-
4
provides
the
Calibration
Error
LED
Blink
indications
.
DS1
NOTE:
If
the
WBA
-
1X
does
not
enter
diagnostic
mode
(i
.
e
.
,
The
LED
is
constantly
OFF
(out)
or
constantly
ON
(lit),
a
CPU
problem
may
exist
.
Re
-
flash
the
unit
(if
a
WBA
10/12/14)
or
change
the
EPROM
(if
a
WBA
11/13/15)
.
NOTE:
The
setting
of
DIP
Switch
8
to
ON
again
will
interrupt
a
test,
and
restore
the
system
to
the
Test
Mode
.
DS1
NOTE:
The
Test
LED
on
the
Power
Supply
or
the
Bezel
Lamps
will
blink
rapidly
if
the
calibration
was
successful
.
NOTE:
Use
calibration
paper
part
number
501
-
000032
for
the
WBA
-
1X
.
Table
A
-
4
WBA
-
1X
Calibration
Error
Indications
Number
of
LED
Blinks
Description
Possible
Cause
1
Entrance
Lever
Error
Check
the
PLEV/FLEV
Sensor
2
Solenoid
Error
Check
the
Solenoid
in
the
Transport
3
Feed
Sensor
Error
Check
the
Entrance
Sensor
in
the
Transport
4
Transport
Jamming
Check
the
Entrance
Sensor
in
the
Transport