JCM
Part
No
.
960
-
000076R
_
Rev
.
1
©
2007,
JCM
-
American
Corporation
A
-
5
Troubleshooting
World
Bill
Acceptor
(WBA®
-
1x/2x
-
SS
&
SS2)
Appendix A
Diagnostic
Test
Mode
To
enter
the
Diagnostic
Test
Mode
perform
the
following
steps:
1
.
Set
DS1
DIP
Switch
No
.
8
on
the
CPU
Board
to
ON
and
DIP
Switches
1
thorough
7
to
OFF
.
2
.
Apply
power
and
observe
that
one
of
the
following
conditions
occur:
The
test
LED/Bezel
light
blinks
at
a
steady
rate,
indicating
diagnostic
mode
is
active
The
WBA
-
1X
does
not
enter
diagnostic
mode
The
LED
is
constantly
OFF
(out)
or
ON
(lit)
A
CPU
problem
exists
[Re
-
flash
the
unit
(WBA
10/12/14)
or
change
the
EPROM
(WBA
11/13/15)]
.
Functional
Tests
Table
A
-
5
provides
a
DIP
Switch
settings
chart
for
performing
WBA
-
1X
Functional
Tests
.
Head
Sensor
Test
(PH06)
Perform
the
following
steps
to
enter
the
Head
Sensor
Test:
1
.
Enter
diagnostic
mode
DIP
Switch
No
.
8,
to
ON
.
2
.
Apply
power
to
the
WBA
Unit
.
3
.
Turn
DIP
Switch
No
.
6,
ON
and
turn
DIP
Switch
No
.
8,
OFF
.
This
activates
the
Head
Sensor
Test
.
DIP
Switch
No
.
6
will
now
be
used
as
the
Enable/Disable
function
switch
for
these
tests
.
5
Gain
Error
(White
level
adjustment
error)
If
the
reference
paper
was
loaded
correctly,
change
the
Upper
Sensor
Board
6
Digital/Analog
Error
If
the
reference
paper
was
loaded
correctly,
change
the
Upper
Sensor
Board
7
Bar
Sensor
Error
Change
the
Upper
Sensor
Board
8
Acceptor
Head
Removed
Check
condition
of
the
20
pin
connector
that
connects
head
to
the
CPU
Board
9
Magnetic
Setting
Error
Change
the
Upper
Sensor
Board
10
Write
-
in
Error
Change
the
Upper
Sensor
Board
11
Black
Level
Error
Replace
the
Upper
or
Lower
Sensor
board
Table
A
-
4
WBA
-
1X
Calibration
Error
Indications
(Continued)
Number
of
LED
Blinks
Description
Possible
Cause
Table
A
-
5
WBA
-
1X/2X
Functional
Test
DIP
Switch
Settings
Test
DIP
Switch
Positions
Functional
Test
No
.
8
7
6
5
4
3
2
1
1
E/D
*
X
Transfer
Motor
Forward
Rotation
Test
(test
light
OFF
=
motor
speed
OK)
2
E/D
X
Transfer
Motor
Reverse
Rotation
Test
(test
light
OFF
=
motor
speed
OK)
3
E/D
X
Stacker
Motor
and
Pusher
Mechanism
Test
4
E/D
X
Acceptor
Head/Stacker
Test
(Use
Error
Table
A
-
11
only)
5
E/D
X
X
Acceptor
Stacker
Test
without
the
head
(Use
Error
Table
A
-
11
only)
6
E/D
X
Solenoid
Test
7
E/D
X
Acceptor
Head
Sensor
Test
(PH06)
8
E/D
X
Transport
Sensor
Test
(PH07)
9
E/D
X
X
X
Bill
Acceptance
Test
without
Cash
Box
and
Frame
(Error
Table
A
-
10
or
Table
A
-
12)
10
E/D
X
X
X
X
Bill
Acceptance
Test
with
Cash
Box
and
Frame
(Error
Table
A
-
10
or
Table
A
-
12)
*
.
E/D
=
Enable/Disable
.
X
=
ON