Troubleshooting
World
Bill
Acceptor
(WBA®
-
1x/2x
-
SS
&
SS2)
Appendix A
Bill
Acceptance
Test
There
are
two
ways
to
run
the
Bill
Acceptance
Test:
1
.
With
a
separate
head
and
transport
.
The
Cash
Box
Sensor
(S2)
and
Stacker
Home
Sensor
(S1)
are
disabled
and
not
tested
.
2
.
With
a
head
and
transport
inserted
into
a
frame
containing
a
Cash
Box
.
All
sensors
and
functions
are
tested
.
Bill
Acceptance
Test
Modes
To
Enter
a
Bill
Acceptance
mode:
1
.
Turn
DIP
Switch
No
.
8
ON
,
apply
power
(diagnostic
mode)
and:
Turn
the
related
DIP
Switches
ON
according
to
the
Table
A
-
8
chart
settings
The
unit
will
cycle
and
be
ready
to
accept
and
identify
bills
.
Bill
Identification
in
Bill
Acceptance
Bill
identification
is
done
by
counting
the
LED
flashes
after
a
bill
is
validated
as
follows:
1
flash
=
$1
2
flashes
=
$2
(not
programmed)
3
flashes
=
$5
4
flashes
=
$10
5
flashes
=
$20
6
flashes
=
$50
7
flashes
=
$100
8
flashes
=
Bar
Code
Ticket
.
Forced
Download
Mode
Perform
the
following
steps
to
initiate
a
Forced
Download:
1
.
Select
the
appropriate
download
speed
(see
the
Table
A
-
9
Chart)
.
2
.
Connect
the
WBA
-
1X
per
the
download
tool
requirement
.
3
.
Power
up
the
WBA
-
1X
.
DT
-
004
Downloading
Perform
the
following
steps
to
initiate
a
DT
-
004
Download:
1
.
Connect
the
DT
-
004
(Part
No
.
501
-
000022R)
to
the
PS15
-
006
power
supply
(Part
No
.
550
-
100042R)
.
Or
at
game
use
adapter
harness
(Part
No
.
400
-
100068R
for
a
WBA
10
or
Part
No
.
400
-
100069R
for
a
WBA
12)
.
2
.
Install
the
appropriate
master
EPROM
chip
into
the
DT
-
004
.
Table
A
-
8
WBA
-
1X/2X
Bill
Acceptance
Test
Setting
Chart
DIP
Switch
Positions
Bill
Acceptance
Test
Activated
8
7
6
5
4
3
2
1
E/D
*
X
X
X
Bill
Acceptance
Test
without
Cash
Box
and
Frame
E/D
X
X
X
X
Bill
Acceptance
Test
with
Cash
Box
and
Frame
*
.
E/D
=
Enable/Disable
.
X
=
ON
Table
A
-
8
provides
the
DIP
Switch
settings
for
performing
the
WBA
-
1X/2X
Bill
Acceptance
Tests
.
NOTE:
Switch
#1
needs
to
be
turned
OFF
after
the
Bill
Acceptance
Test
has
started
to
enable
Bar
Code
ticket
reading
(ID003
Software)
.
NOTE:
For
multiple
WBA
-
1X
downloads,
refer
to
the
Multi
-
Download
Adapter
Kit
Users
Manual
(Part
No
.
701
-
000031R)
.
Table
A
-
9
WBA
-
1X/2X
Forced
Download
Mode
Chart
DIP
Switch
Positions
Download
Speed
Selected
8
7
6
5
4
3
2
1
X
*
X
9,600
Baud
-
WBA
10
or
WBA
12/14
X
X
X
19,200
Baud
-
WBA
10
or
WBA
12/14
X
X
X
X
38,400
Baud
-
WBA
12/14
*
.
X
=
ON
Table
A
-
9
provides
the
DIP
Switch
settings
for
performing
various
WBA
-
1X/2X
Forced
Download
NOTE:
The
default
speed
for
downloading
a
single
unit
is
19200
baud
.