JCM Part No . 960 - 000076R _ Rev . 1 © 2007, JCM - American Corporation A - 9 Troubleshooting World Bill Acceptor (WBA® - 1x/2x - SS & SS2) Appendix A Bill Acceptance Test There are two ways to run the Bill Acceptance Test: 1 . With a separate head and transport . The Cash Box Sensor (S2) and Stacker Home Sensor (S1) are disabled and not tested . 2 . With a head and transport inserted into a frame containing a Cash Box . All sensors and functions are tested . Bill Acceptance Test Modes To Enter a Bill Acceptance mode: 1 . Turn DIP Switch No . 8 “ON” , apply power (diagnostic mode) and: Turn the related DIP Switches ON according to the Table A - 8 chart settings   The unit will cycle and be ready to accept and identify bills .   Bill Identification in Bill Acceptance Bill identification is done by counting the LED flashes after a bill is validated as follows:   1 flash = $1   2 flashes = $2 (not programmed)   3 flashes = $5   4 flashes = $10   5 flashes = $20   6 flashes = $50   7 flashes = $100   8 flashes = Bar Code Ticket . Forced Download Mode Perform the following steps to initiate a Forced Download: 1 . Select the appropriate download speed (see the Table A - 9 Chart) . 2 . Connect the WBA - 1X per the download tool requirement . 3 . Power up the WBA - 1X . DT - 004 Downloading Perform the following steps to initiate a DT - 004 Download: 1 . Connect the DT - 004 (Part No . 501 - 000022R) to the PS15 - 006 power supply (Part No . 550 - 100042R) . Or at game use adapter harness (Part No . 400 - 100068R for a WBA 10 or Part No . 400 - 100069R for a WBA 12) . 2 . Install the appropriate master EPROM chip into the DT - 004 . Table A - 8 WBA - 1X/2X Bill Acceptance Test Setting Chart DIP Switch Positions Bill Acceptance Test Activated 8 7 6 5 4 3 2 1 E/D * X X X Bill Acceptance Test without Cash Box and Frame E/D X X X X Bill Acceptance Test with Cash Box and Frame * . E/D = Enable/Disable . X = ON Table A - 8 provides the DIP Switch settings for performing the WBA - 1X/2X Bill Acceptance Tests . NOTE: Switch #1 needs to be turned OFF after the Bill Acceptance Test has started to enable Bar Code ticket reading (ID003 Software) . NOTE: For multiple WBA - 1X downloads, refer to the Multi - Download Adapter Kit Users Manual (Part No . 701 - 000031R) . Table A - 9 WBA - 1X/2X Forced Download Mode Chart DIP Switch Positions Download Speed Selected 8 7 6 5 4 3 2 1 X * X 9,600 Baud - WBA 10 or WBA 12/14 X X X 19,200 Baud - WBA 10 or WBA 12/14 X X X X 38,400 Baud - WBA 12/14 * . X = ON Table A - 9 provides the DIP Switch settings for performing various WBA - 1X/2X Forced Download NOTE: The default speed for downloading a single unit is 19200 baud .